{"product_id":"cp0803e8-channel-power-sequencer","title":"CP0803E(8-Channel Power Sequencer)","description":"\u003ch1\u003e\u003cstrong\u003e8-Channel Power Sequencer\u003c\/strong\u003e\u003c\/h1\u003e\n\u003ch1\u003e\n\u003cb\u003e\u003cspan\u003e\u003cspan style=\"font-family: Calibri;\"\u003eIntroduction:\u003c\/span\u003e\u003c\/span\u003e\u003c\/b\u003e\u003cb\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/b\u003e\n\u003c\/h1\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003e\u003cspan style=\"font-family: Calibri;\"\u003e1) When the audio system does not turn on the devices in the normal order, the system may amplify the introduced noise signal at the moment of power on, resulting in a strong whistling sound. In severe cases, it may damage the rear amplifier or speakers;\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003e\u003cspan style=\"font-family: Calibri;\"\u003e2) When a large number of electrical equipment such as cabinets are powered on simultaneously, a strong instantaneous surge current will be generated due to the superposition effect of current, which will seriously threaten the safety of electrical equipment and may even damage it in severe cases.\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv data-page-id=\"KM5hdqBwzopEWpxz4bdcZwvQnk3\" data-lark-html-role=\"root\" data-docx-has-block-data=\"false\"\u003e\n\u003cdiv data-type=\"divider\" class=\"old-record-id-UtHQf6wK1dd889c57sLcmMwCnDh\"\u003e\u003chr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch1\u003e\n\u003cb\u003e\u003cspan\u003e\u003cspan style=\"font-family: Calibri;\"\u003eFunctional\u003c\/span\u003e\u003c\/span\u003e\u003c\/b\u003e\u003cb\u003e\u003cspan\u003e \u003cspan style=\"font-family: Calibri;\"\u003echaracteristics of power sequencer:\u003c\/span\u003e\u003c\/span\u003e\u003c\/b\u003e\u003cb\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/b\u003e\n\u003c\/h1\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003e\u003cspan style=\"font-family: Calibri;\"\u003e1) Three working modes can be set: master mode (cascaded master), slave mode (cascaded slave), and single control central control mode\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003e\u003cspan style=\"font-family: Calibri;\"\u003e2) 8-channel sequential power output;\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003e\u003cspan style=\"font-family: Calibri;\"\u003e3) Timing switch, used to control the sequential \"positive sequence\" on and \"reverse sequence\" off of 8 timing power supplies, with a timing interval of 1 second for each circuit;\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003e\u003cspan style=\"font-family: Calibri;\"\u003e4) 8 single control buttons, which can manually control the on and off of each timing output power supply;\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003e\u003cspan style=\"font-family: Calibri;\"\u003e5) Equipped with three-phase AC voltage display function, it can display the current AC voltage value of each phase of power supply, facilitating real-time monitoring of the current working voltage;\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003e\u003cspan style=\"font-family: Calibri;\"\u003e6) This device supports three-phase five wire power input, with a total input current of: 32A x 3=96A\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003e\u003cspan style=\"font-family: Calibri;\"\u003e7) 8 audio power output sockets, with a maximum working current of 10A per channel (not exceeding this maximum value);\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003e\u003cspan style=\"font-family: Calibri;\"\u003e8) Configuring overcurrent protection air switches can provide real-time power-off protection for circuit overload or short circuit faults, preventing electrical equipment from burning out and avoiding accidents such as fires caused by overheating of the circuit;\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003e\u003cspan style=\"font-family: Calibri;\"\u003e9) Applied to centralized power management and control of devices, its standard cabinet installation characteristics are more suitable for large-scale power management and control needs;\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003e\u003cspan style=\"font-family: Calibri;\"\u003e10) Equipped with the function of keeping the lock switch, it is used to lock the current switch status and prevent the equipment from being powered off due to misoperation during operation;\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003e\u003cspan style=\"font-family: Calibri;\"\u003e11) Multiple cascaded devices can be implemented, making it easy to expand into more sequential power output channels;\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003e\u003cspan style=\"font-family: Calibri;\"\u003e12) The timing switch, switch indicator light, and lock switch can be externally controlled according to the connection method provided in the manual, and the control switch can be installed in other convenient places;\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003e\u003cspan style=\"font-family: Calibri;\"\u003e13) Equipped with remote central control triggering mode, it can send instructions through the RS485 port to remotely control the operation of the timing device.\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003e\u003cspan style=\"font-family: Calibri;\"\u003e14) 1.5U chassis suitable for cabinet installation, screw installation\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003e\u003cspan style=\"font-family: Calibri;\"\u003e15) Supports switching between two working voltages: 110 or 220V\/50-60HZ\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e","brand":"Eagle Light","offers":[{"title":"Default Title","offer_id":53692663038320,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0964\/3691\/2496\/files\/1_89da0cf1-ffa3-46c4-be31-f2abe894373c.jpg?v=1777269706","url":"https:\/\/eaglelightpro.com\/products\/cp0803e8-channel-power-sequencer","provider":"Eagle Light","version":"1.0","type":"link"}